Security Governance · Topic 2 of 3

Business Continuity and Disaster Recovery

Redundancy for the CC exam: business continuity and disaster recovery plans, the BIA, RTO and RPO, backups, failover, load balancing, sites and AI model drift.

  • 3 min
In a nutshell
  • BC keeps the business running; DR restores IT.
  • The BIA comes first and sets RTO and RPO.
  • RTO is time to recover; RPO is acceptable data loss.

What it is

Redundancy keeps an organization working when something fails. Business continuity (BC) keeps critical business functions running during a disruption. Disaster recovery (DR) restores IT systems and data after a disruption. Both depend on duplicates: of data, systems, sites and suppliers.

Business impact analysisRecovery targetsRTO and RPORedundancybackups, failover, sitesPlansTests

How it works

BC and DR

Business continuityDisaster recovery
FocusKeeping the business runningRestoring IT systems and data
ScopePeople, processes, suppliers, facilities, ITMainly technology
ExampleStaff work from another officeServers restored at a recovery site

Both start with a business impact analysis (BIA), which finds the critical functions and how long the business can survive without them.

Recovery targets

TermMeaning
RTO (recovery time objective)How quickly a system must be back
RPO (recovery point objective)How much recent data may be lost

Redundancy techniques

TechniqueWhat it does
BackupsCopies of data to restore after loss
FailoverA standby system takes over when the primary fails
Load balancingSpreads requests across several servers so none is overloaded
ReplicationKeeps copies of data on more than one system
Redundant powerUPS and generators
Alternate sitesHot (ready to go), warm (partly ready) or cold (space and power only)
Second supplierRemoves dependence on one provider
Exam tip

Backups protect data but may take hours to restore. To keep a service running through a site outage, you need a standby at a second site with failover.

Redundancy for AI systems

  • Back up the model files and training data, not just reports or servers, so you can restore the model's behaviour.
  • Plan for model drift: a model's accuracy can fall as real-world behaviour changes. The fix is to monitor accuracy and retrain, not failover or backups.
  • Avoid depending on a single external AI provider with no fallback.

Testing plans

Plans must be tested: walkthroughs and tabletop exercises, simulations, parallel tests and, rarely, full interruption tests. Untested plans often fail when needed.

How the exam asks about this

  • "Which approach spreads requests across several servers?" Load balancing.
  • "A fraud model grows less accurate over the year." Monitor accuracy and retrain.
  • "Which plan keeps business functions running during a disruption?" The business continuity plan.

What to remember for the exam

  • BC keeps the business running; DR restores IT.
  • The BIA comes first and sets RTO and RPO.
  • RTO is time to recover; RPO is acceptable data loss.
  • Backups, failover, load balancing, replication and alternate sites provide redundancy.
  • For AI, back up models and training data, and watch for model drift.
Watch out

A bigger server at the same site does not help when the whole site is down. Redundancy must avoid shared points of failure.

Common mistakes

Confusing BC with DR.

Mixing up RTO and RPO.

Treating backups as instant availability.

Check yourself

  • What does RPO measure?

    How much recent data the business can afford to lose.

  • Which plan restores IT systems after a disaster?

    The disaster recovery plan.

  • What should be backed up to restore an AI tool's behaviour?

    The model files and the training data.

Topic 2 of 3 in Security Governance

Test yourself on Security Governance

The full ISC2 CC question bank has 671 questions, with timed practice exams and an explanation for every answer.